PDF Bachelor of Science in Biomedical Engineering

EBM 501 Lesson 1: Electrophysiological Measurements, Group Presentation

Group presentation covering the first lesson of the unit: the origin of bioelectric potentials in the cell, the nerve and muscle signals available for measurement, the electrode systems and lead configurations, and the instrumentation chain from the amplifier to the display.

Document preview

Page 1 of 63 · first page only

PDF

More materials from the same course.

EBM 510: Electric Motor Drive Systems Continuous Assessment Test Forty-minute continuous assessment paper on electric motor drive systems in which any three of six questions are answered. A three-phase fifty-hertz induction motor with equal stator and rotor resistances of five hundredths of an ohm and reactances of three tenths of an ohm, run at half its rated voltage and half its rated frequency: the maximum torque at the reduced supply as a fraction of its normal value. The wound-rotor induction motor rated twenty-five kilowatts at nine hundred revolutions per minute on four hundred and fifteen volts, fed through a three-phase rectifier and a chopper at two hundred and fifty hertz with an open-circuit line voltage of three hundred and fifty volts and a one-ohm load resistance: the chopper on-time that develops a gross torque of one hundred and eighty newton metres at eight hundred revolutions per minute against a synchronous speed of one thousand. For a synchronous motor, three torques associated with it and two methods of starting it. The derivation of the expression relating torque and speed of a cylindrical rotor synchronous motor. A four-pole induction motor on a fifty-hertz supply: synchronous speed, rotor speed at five per cent slip, and rotor frequency when the rotor runs at one hundred revolutions per minute. And the labelled torque-speed characteristic of an induction motor showing the plugging, motoring and generating regions, with regenerative braking explained. PDF KES 40.00 Open Biomedical Engineering Education in Africa (IEEE EMBC conference paper) Conference paper on opening biomedical engineering teaching in Africa through shared curricula and remote collaboration between African and European institutions. PDF KES 40.00 EBM 506: Biomechanics II CAT 2 Assignment Submission Team submission answering the second continuous assessment: the five design attributes of a total knee replacement with the motion, forces, geometry, constraint and replicability of the natural knee against what the implants achieve, the limitations met in designing a replacement, and a systematic review of the engineering standards currently in use for total knee replacement implants in the United Kingdom and the United States, with the premarket testing the implant scandals brought to attention. PDF KES 40.00 ECU 402: Engineering Economics Discussion Task on Inflation Discussion task setting three questions: defining inflation, explaining how inflation is measured, and tracing the monthly inflation rate in Kenya with labelled diagrams and graphs, including the months of highest and lowest readings and what caused them. PDF KES 40.00 EBM 406: Hospital Engineering Management Continuous Assessment Test II Second continuous assessment test for the unit, sat on 30 January 2021 in the Department of Electrical and Electronics Engineering, opening on the role of the World Health Organization in the provision of healthcare. PDF KES 40.00