list_alt All Notes

PDF 208 KB 6 weeks ago

EMM 314: Manufacturing Work Study Trimester Examination

Asks which factors cause variation in an element's time during time study, the disadvantages of work sampling, and the predetermined time study approach to work measurement, then computes standard time from observed times, ratings and frequencies with a rest and personal allowance of twelve per cent. Requires a two-handed process chart for assembling two washers and a nut to a bolt from a written description of the hands' movements, together with the operator's ideal layout. Continues with the areas where methods study applies, the purposes of micromotion study, a standard time from a five-element study with personal and contingency allowances, a work sampling study of a component produced over five days, the jobs likely to be chosen in operation analysis, and the balance of an assembly line over an eight hour shift: total work content, maximum shift output, number of work stations, efficiency and idleness.

Bachelor of Science in Mechanical Engineering · Mechanical Engineering · Year 3
PDF 233 KB 6 weeks ago

EMM 314: Manufacturing Work Study First Semester Examination

Opens on why methods study is applied in manufacturing and in services and what work measurement achieves, then sets a machine operation with movements to and from stores and a wait at an inspection bench: construct the process chart, analyse it against the principles of motion economy and simplify it. Asks what is considered when selecting a job for direct time study, and computes standard time per piece from a three-day work sampling study with recorded observations of manual work, machine work and idle time at a stated performance rating and allowance. Closes on the advantages of work sampling over time study, work study as an aid to management, the same assembly line balance over an eight hour shift, the areas where methods study improves work methods, and the predetermined time study approach.

Bachelor of Science in Mechanical Engineering · Mechanical Engineering · Year 3
PDF 198 KB 6 weeks ago

EMM 308: Computer Programming II First Semester Examination

Programming paper set around C#.Net. Differentiates value and reference types with a worked example, and treats encapsulation, polymorphism and abstraction, the structure of exception handling illustrated by catching a division by zero error, the data structures commonly used in programs and the considerations that go into designing a user interface. The practical questions write programs: capturing machine names in a list and displaying them sorted in a list box, capturing customer account details on a window form and submitting them to an external file, retrieving equipment records from a text file into a data grid view, and a console program that records machinery details and presents them in sorted tabular form. Also weighs command line against graphical interfaces, the shortcomings of component-based applications, dialog boxes, access modifiers, multi-tier architecture and the stages of component-based development.

Bachelor of Science in Mechanical Engineering · Mechanical Engineering · Year 3
PDF 4.9 MB 6 weeks ago

Application for the certificate in emergency Medical Technician

A comprehensive 2 years pre-hospital emergency care program focus on patient assessment,trauma management, CPR and BLS stabilization.

Diploma in Emergency Medical Technology · Emergency Medical Technology · Certificate
PDF 379 KB 6 weeks ago

X-Ray Machines and Digital Radiography

Slides on diagnostic radiology, which works because different body structures have different permeability to X-rays. Covers the production of the rays and the interactions that matter in image formation, and the three ways of quantifying radiation: exposure in roentgens, absorbed dose in rads and the relative biological damage in rems. Contrasts viewing an image directly on a fluorescent screen, which is relatively faint, needs a dark room and forces the radiologist to acclimatise, with digital radiography and its easier post-processing, lower doses and the possibility of digital storage, and closes on the physical parameters used to rate a detector, beginning with detector quantum efficiency.

Bachelor of Science in Biomedical Engineering · Biomedical Engineering · Bachelors
PDF 385 KB 6 weeks ago

X-Ray Computed Tomography

Slides on computed tomography, which overcomes the limitations of two-dimensional radiography by forming a three-dimensional image and making soft tissue easy to view. Takes the machine apart: the gantry geometry, the computer that presents the information in visual form together with the manipulative aids that assist diagnosis, and the storage unit that keeps studies for subsequent analysis. Notes that technical advancement has been in speed and application while the basic concept has stayed much the same, and treats patient dose, where image noise falls only if the dose is raised, with typical head and body doses of 2.5 rads and 1 to 2 rads, and what multi-slice operation changes.

Bachelor of Science in Biomedical Engineering · Biomedical Engineering · Bachelors
PDF 376 KB 6 weeks ago

Nuclear Medical Imaging Systems

Slides on radio isotopes, used for both diagnosis and therapy, where a small amount of radioactivity is introduced into the body and traced from outside. The curie is defined as 3.7 by ten to the tenth disintegrations per second, and organ scanning typically uses three to twenty-five millicuries. Covers radiation detection and the pulse height analyser, since the radioactive pulses arrive as single electrical impulses and the height of the impulse tells you the energy of the particle that produced it, the scintillation crystal coupled to photomultipliers, and the multicrystal gamma camera, which overcomes the losses of a single crystal by using a rectangular array of crystals with reflective material to minimise scattering.

Bachelor of Science in Biomedical Engineering · Biomedical Engineering · Bachelors
PDF 426 KB 6 weeks ago

Magnetic Resonance Imaging System

Slides on magnetic resonance imaging, built on nuclear magnetic resonance tomography, which uses magnetic fields and radio frequency signals to obtain anatomical information. Works through the reconstruction techniques, including the sequential point method, which divides the sample volume into points along three axes and so fixes the number of NMR signal values that must be acquired, and through the parts of the system: the magnet and its field, the gradient coils, the radio frequency system, the detection system that yields the output signal and the imager that reconstructs and displays the images. Treats biological effects, with heating among the potential hazards, and the advantages of the method, superior contrast between near-identical soft tissues, cross-sectional images in any orientation rather than only at right angles as in computed tomography, and contrast that can be chosen by mechanism.

Bachelor of Science in Biomedical Engineering · Biomedical Engineering · Bachelors
PDF 356 KB 6 weeks ago

Ultrasonic Imaging Systems

Slides on diagnostic ultrasound, which excels because it is non-invasive, externally applied, non-traumatic and safe. Explains that ultrasound is a mechanical vibration and so needs a medium to travel through, and that its velocity of propagation is almost constant across body tissues, which is what makes depth of penetration a function of transit time. Sets out the pulse-echo technique, transmitting a train of short bursts and receiving the echoes, which is far easier to measure than a continuous wave and is the basis of both echoencephalographs and echocardiographs, and closes on biological effects, where the consensus of repeated studies is that no significant hazard attaches to diagnostic levels of ultrasound.

Bachelor of Science in Biomedical Engineering · Biomedical Engineering · Bachelors
PDF 327 KB 6 weeks ago

Thermal Imaging Systems

Slides on medical thermography, the science of visualising the patterns formed by changes in skin temperature with an infrared camera. Covers the radiation physics that decides what the camera can see, including absorption and its effect on emissivity and the fact that the human body is almost opaque to the infrared wavelengths used, and the detector, where the smallest temperature change that produces a signal equal to the system noise is the minimum temperature resolution and so defines the sensitivity of the equipment. Distinguishes quantitative thermography, in which successive studies must be made comparable, from the qualitative picture, and describes the detectors used, including the image tube that focuses the radiation onto an infrared-sensitive target and the camera built on an infrared sensor with a digital focal plane array.

Bachelor of Science in Biomedical Engineering · Biomedical Engineering · Bachelors
PDF 280 KB 6 weeks ago

Biomedical Instrumentation III Assignment Briefs

The two assignment briefs set for the unit. The first is on temperature monitoring, opening from body temperature as one of the vital physiological signals monitored in patients, normally taken with a rectal thermistor probe, with the accompanying instrumentation carrying an alarm that is activated when temperature falls outside stable conditions and the thermistor named as the common transducer used in patient monitoring systems; the brief prescribes an introduction, a body and a conclusion and requires a compilation. The second is a term paper on telemedicine to be written under concepts, parameters, technologies and applications.

Bachelor of Science in Biomedical Engineering · Biomedical Engineering · Bachelors
PDF 1.3 MB 6 weeks ago

Machine Design: Product Innovation Processes and Life Cycle Thinking

Machine design lecture slides on how a design activity is started and organised. The opening questions decide which approach will realise the design goal: what the goal is, the resources, time and budget available, the expertise and infrastructure on hand, who the stakeholders are with their needs, desires and wishes, and who will do the work with what skills, attitudes and ambitions. A second block asks how the work is then divided among team members, what the dependencies between activities are, which milestones are necessary and what intermediate results must be delivered. The course moves into models of the product innovation process, from strategic product position and linear logic to circular chaos, then design in and for emerging economies, where bottom-of-the-pyramid projects have poor and vulnerable intended users and so raise sustainability separately, and finishes with life cycle stages: production and supply of materials, manufacture, distribution with less, cleaner or reusable packaging and energy-efficient transport and logistics modes, and utilisation.

Bachelor of Science in Biomedical Engineering · Biomedical Engineering · Bachelors