list_alt All Notes

PDF 356 KB 6 weeks ago

Ultrasonic Imaging Systems

Slides on diagnostic ultrasound, which excels because it is non-invasive, externally applied, non-traumatic and safe. Explains that ultrasound is a mechanical vibration and so needs a medium to travel through, and that its velocity of propagation is almost constant across body tissues, which is what makes depth of penetration a function of transit time. Sets out the pulse-echo technique, transmitting a train of short bursts and receiving the echoes, which is far easier to measure than a continuous wave and is the basis of both echoencephalographs and echocardiographs, and closes on biological effects, where the consensus of repeated studies is that no significant hazard attaches to diagnostic levels of ultrasound.

Bachelor of Science in Biomedical Engineering · Biomedical Engineering · Bachelors
PDF 327 KB 6 weeks ago

Thermal Imaging Systems

Slides on medical thermography, the science of visualising the patterns formed by changes in skin temperature with an infrared camera. Covers the radiation physics that decides what the camera can see, including absorption and its effect on emissivity and the fact that the human body is almost opaque to the infrared wavelengths used, and the detector, where the smallest temperature change that produces a signal equal to the system noise is the minimum temperature resolution and so defines the sensitivity of the equipment. Distinguishes quantitative thermography, in which successive studies must be made comparable, from the qualitative picture, and describes the detectors used, including the image tube that focuses the radiation onto an infrared-sensitive target and the camera built on an infrared sensor with a digital focal plane array.

Bachelor of Science in Biomedical Engineering · Biomedical Engineering · Bachelors
PDF 280 KB 6 weeks ago

Biomedical Instrumentation III Assignment Briefs

The two assignment briefs set for the unit. The first is on temperature monitoring, opening from body temperature as one of the vital physiological signals monitored in patients, normally taken with a rectal thermistor probe, with the accompanying instrumentation carrying an alarm that is activated when temperature falls outside stable conditions and the thermistor named as the common transducer used in patient monitoring systems; the brief prescribes an introduction, a body and a conclusion and requires a compilation. The second is a term paper on telemedicine to be written under concepts, parameters, technologies and applications.

Bachelor of Science in Biomedical Engineering · Biomedical Engineering · Bachelors
PDF 1.3 MB 6 weeks ago

Machine Design: Product Innovation Processes and Life Cycle Thinking

Machine design lecture slides on how a design activity is started and organised. The opening questions decide which approach will realise the design goal: what the goal is, the resources, time and budget available, the expertise and infrastructure on hand, who the stakeholders are with their needs, desires and wishes, and who will do the work with what skills, attitudes and ambitions. A second block asks how the work is then divided among team members, what the dependencies between activities are, which milestones are necessary and what intermediate results must be delivered. The course moves into models of the product innovation process, from strategic product position and linear logic to circular chaos, then design in and for emerging economies, where bottom-of-the-pyramid projects have poor and vulnerable intended users and so raise sustainability separately, and finishes with life cycle stages: production and supply of materials, manufacture, distribution with less, cleaner or reusable packaging and energy-efficient transport and logistics modes, and utilisation.

Bachelor of Science in Biomedical Engineering · Biomedical Engineering · Bachelors
PDF 423 KB 6 weeks ago

Electric Drives and the Speed Control of DC Motors

Course notes on electric drives, beginning with the drive as a combination of prime mover, transmission equipment and mechanical load and the electric drive as the electromechanical device that converts electrical energy into mechanical energy to impart motion to different machines. Establishes the major advantage of the direct current motor over the alternating current motor as the relative ease of speed control, achieved either by varying the voltage or the field flux, with the voltage varied from zero up to rated speed and the flux weakened above it, and works through the armature-voltage and field-control methods, the chopper and converter circuits that supply them, and the back electromotive force and armature resistance equations from which the operating point is calculated.

Bachelor of Science in Biomedical Engineering · Biomedical Engineering · Bachelors
PDF 493 KB 6 weeks ago

Three-Phase Induction Motor Drives and Their Torque Characteristics

Notes on the induction motor, contrasted with the direct current machine where conductors on a rotating armature pass through a stationary magnetic field: here the magnetic field rotates, so no electrical connection has to be made to the rotor. Develops the slip, the equivalent circuit and the three-phase torque expression, showing that with a constant supply voltage torque is proportional to slip resistance over the impedance term and is therefore maximum when rotor resistance equals rotor reactance. Works through the torque-speed characteristics in the forward and reverse directions and the operating cases of motoring, plugging and generating at slip one and slip zero, and continues into the methods of controlling the machine.

Bachelor of Science in Biomedical Engineering · Biomedical Engineering · Bachelors
PDF 279 KB 6 weeks ago

AC-DC Converters for Variable Speed Drives

Notes on the controlled rectifiers used as ac-dc converters in industrial variable speed drives, classified into single-phase and three-phase forms and within each into semi, full and dual converters. The quadrant map is the organising device: a semi-converter is a one-quadrant converter with a single polarity of output voltage and current, a full converter is two-quadrant and a dual converter four-quadrant. Works through the single-phase semi-converter with a highly inductive load, its freewheeling operation and the better power factor it gives and the applications up to fifteen kilowatts for which it is used, with the output voltage and current waveforms and the average-voltage calculation for each configuration.

Bachelor of Science in Biomedical Engineering · Biomedical Engineering · Bachelors
PDF 78 KB 6 weeks ago

Electric Motor Drive Systems Course Description

The unit description, in two halves. Direct current machine drives: two and four quadrant chopper control, the transfer function of the direct current machine drive system, speed and current feedback control, microprocessor control of direct current drives and variable speed drives. Alternating current machine drives: the a.c. machine system, induction and synchronous motor drives, electronic control using inverters, harmonic distortion and losses, control of frequency, voltage and power, transfer functions of a.c. machine drive systems, speed, current and flux feedback, microprocessor control in a.c. drives and the applications of a.c. variable speed drives.

Bachelor of Science in Biomedical Engineering · Biomedical Engineering · Bachelors
PDF 21 KB 6 weeks ago

EBM 510 Tutorial Questions One

First tutorial sheet on direct current drives. Questions include a constant-frequency system controlling the speed of a direct current traction motor from a 250-volt supply with combined armature and field resistance of a quarter of an ohm, average current of twenty amperes and a chopper frequency of 176 hertz, where the pulse width must be found for an average back electromotive force of 100 volts; and a chopper-controlled separately excited motor on a 220-volt supply with armature resistance of 0.2 ohms and a motor constant of 0.08 per rpm driving a constant-torque load that requires twenty-five amperes of average armature current.

Bachelor of Science in Biomedical Engineering · Biomedical Engineering · Bachelors
PDF 176 KB 6 weeks ago

EBM 510 Tutorial Questions One: Worked Solutions

Worked answers to the first tutorial, showing the arithmetic rather than only the result. The pulse-width question is solved from the armature circuit equation, average voltage equal to armature current times the sum of armature and field resistance plus back electromotive force, giving 105 volts and then the on-time from the average voltage, supply and frequency, at 2.386 milliseconds; the second begins from the case of zero back electromotive force to find the starting current, and the remaining questions follow the same route through the chopper on-time, the armature resistance drop and the motor constant.

Bachelor of Science in Biomedical Engineering · Biomedical Engineering · Bachelors
PDF 21 KB 6 weeks ago

EBM 510 Tutorial Questions Two

Second tutorial sheet, on converter-controlled series motors. One question takes a fifteen horsepower, 230-volt, 900 rpm direct current series motor whose speed is controlled by a single-phase semi-converter, with combined armature and field circuit resistance of 0.18 ohms, continuous and ripple-free motor current, a machine constant of 0.04 newton-metres per ampere squared, a firing angle of thirty degrees and a 240-volt alternating supply, and asks for the motor current and motor torque. Another takes a fifteen horsepower, 220-volt, 1000 rpm series motor controlled by a single-phase semi-converter and then a full converter from a 250-volt alternating supply, and a third question continues the comparison of the two converter arrangements.

Bachelor of Science in Biomedical Engineering · Biomedical Engineering · Bachelors
PDF 249 KB 6 weeks ago

EBM 510 Tutorial Questions Two: Worked Solutions

Worked answers to the second tutorial. Torque is taken from the series motor relations, torque proportional to the square of armature current and back electromotive force to current times speed, so that supply voltage equals current times the sum of the speed term and armature resistance; the speed of 1000 rpm is converted to 104.67 radians per second and the half converter's average voltage evaluated from the firing angle at 210 volts, giving 62.87 amperes and 118.59 newton-metres. The same machine is then run on a full converter, whose average voltage of 195 volts gives 58.38 amperes, and the two arrangements are compared.

Bachelor of Science in Biomedical Engineering · Biomedical Engineering · Bachelors